Specifiche Tecniche AHQ-C / AZQS-BY1 UK

AHQ100CV1 / AZQS100B7Y1B UK AHQ125CV1 / AZQS125B7Y1B UK AHQ140CV1 / AZQS140B7Y1B UK
Poff (Modo spento) W 0.0    
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 9.0    
  Cooling-=-Cooling cdc degradation cooling 0.25    
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 9.50    
    Consumo energetico annuale kWh 716    
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 4.60    
    Condizione D (20°C - 27/19) Pdc kW 4.50    
      potenza assorbita kW 0.69    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 6.56    
    Condizione C (25°C - 27/19) potenza assorbita kW 0.81    
      Pdc kW 4.50    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 5.59    
    Condizione A (35°C - 27/19) potenza assorbita kW 3.63    
      Pdc kW 9.50    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 2.62    
    Condizione B (30°C - 27/19) Pdc kW 7.00    
      potenza assorbita kW 1.53    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.58    
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 2,800    
    Pdh - Capacità di riscaldamento a -10° kW 2.89    
    Pdesign kW 7.60    
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.40    
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A    
    TBivalent Pdh (capacità dichiarata di risc.) kW 6.72    
      Potenza assorbita kW 2.42    
      Tbiv (temp. bivalente) °C -7    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.78    
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 3.00    
      Potenza assorbita kW 0.57    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.30    
    TOL Tol (temperatura limite di esercizio) °C -15    
      Pdh (capacità dichiarata di risc.) kW 8.00    
      Potenza assorbita kW 4.17    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.92    
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 6.72    
      Potenza assorbita kW 2.42    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.78    
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 3.50    
      Potenza assorbita kW 0.55    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.42    
    Cond. B (2°C) Potenza assorbita kW 1.17    
      Pdh (capacità dichiarata di risc.) kW 4.10    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.53    
Capacità di Raffrescamento Nom. kW 9.5 12.1 13.0
Pck (Modo riscaldamento del carter) W 0.0    
Efficienza nominale Annual energy consumption kWh 1,810 (0.000) 2,300 (0.000)  
  Classe energetica Riscaldamento D D  
  Nominal efficiency-=-Cop 2.62 2.63 3.01
Riscaldamento Psb (Consumo di energia in modo attesa - riscaldamento) W 9.0    
  Heating-=-Heating cdh degradation heating 0.25    
Capacità di riscaldamento Nom. kW 10.8 13.5 15.5
Pto (Thermostat off) W 149.0    
Potenza assorbita Raffrescamento Nom. kW 3.62 4.60 4.32
  Riscaldamento Nom. kW 3.17 3.74 4.55
Unità interna Sì AZQS125BY1 UK AZQS140BY1 UK
Note Il consumo energetico annuale è conforme alla direttiva 2002/31/CE sulla classificazione energetica Il consumo energetico annuale è conforme alla direttiva 2002/31/CE sulla classificazione energetica Il consumo energetico annuale è conforme alla direttiva 2002/31/CE sulla classificazione energetica
  I valori SEER e SCOP sono conformi alla norma europea EN 14825 I valori SEER e SCOP sono conformi alla norma europea EN 14825 I valori SEER e SCOP sono conformi alla norma europea EN 14825
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale