EHVH04S18CB3V / ERLQ004CAV3 EHVH08S26CB9W / ERLQ006CAV3 EHVH08S18CB3V / ERLQ006CAV3 EHVH08S26CB9W / ERLQ008CAV3 EHVH08S18CB3V / ERLQ008CAV3 EHVH11S18CB3V / ERLQ011CAV3 EHVH11S26CB9W / ERLQ011CAV3 EHVH16S26CB9W / ERLQ014CAV3 EHVH16S18CB3V / ERLQ014CAV3 EHVH16S18CB3V / ERLQ016CAV3 EHVH16S26CB9W / ERLQ016CAV3
Riscaldamento acqua calda sanitaria Generale Profilo di carico dichiarato Sì Sì Sì Sì Sì Sì Sì Sì Sì Sì Sì
  Clima freddo AEC (Consumo elettrico annuale) kWh 1,221 2,037 1,332 2,037 1,332 1,340 1,980 1,980 1,340 1,340 1,980
    Qelec (Consumo elettrico giornaliero) kWh 5.55 9.26 6.05 9.26 6.05 6.08 8.99 8.99 6.08 6.08 8.99
    Ƞwh (efficienza riscaldamento acqua) % 84.0 83.0 77.5 83.0 77.5 76.6 85.1 85.1 76.6 76.6 85.1
    AFC (Consumo di carburante annuale) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Qfuel (Consumo di carburante giornaliero) kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Clima caldo Qelec (Consumo elettrico giornaliero) kWh 4.39 8.11 5.10 8.11 5.10 5.04 7.40 7.40 5.04 5.04 7.40
    AEC (Consumo elettrico annuale) kWh 966 1,784 1,123 1,784 1,123 1,110 1,630 1,630 1,110 1,110 1,630
    Qfuel (Consumo di carburante giornaliero) kWh           0.00 0.00 0.00 0.00 0.00 0.00
    AFC (Consumo di carburante annuale) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (efficienza riscaldamento acqua) % 106 94.0 91.8 94.0 91.8 92.3 103 103 92.3 92.3 103
  Condizioni climatiche medie Ƞwh (efficienza riscaldamento acqua) % 95.0 90.0 86.4 90.0 86.4 87.4 97.7 97.7 87.4 87.4 97.7
    AFC (Consumo di carburante annuale) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Qelec (Consumo elettrico giornaliero) kWh 4.93 8.50 5.43 8.50 5.43 5.32 7.83 7.83 5.32 5.32 7.83
    Qfuel (Consumo di carburante giornaliero) kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    AEC (Consumo elettrico annuale) kWh 1,084 1,871 1,194 1,871 1,194 1,170 1,720 1,720 1,170 1,170 1,720
    Classe di efficienza energetica riscaldamento acqua A A A A A A A A A A A
Riscaldamento ambienti generale Unità salamoia/acqua-acqua Portata nominale acqua/salamoia m³/h     0.00 0.00 0.00            
  Unità aria-acqua Flusso d'aria nominale (esterno) m³/h 2,700 2,820 2,820 2,820 2,820 5,400 5,400 5,400 5,400 5,400 5,400
  Altro Psb (Mod. standby) kW 0.0080 0.0080 0.0080 0.0080 0.0080 0.055 0.055 0.055 0.055 0.055 0.055
    Poff (Mod. spento) kW 0.0080 0.0080 0.0080 0.0080 0.0080 0.055 0.055 0.055 0.055 0.055 0.055
    Pto (Termostato spento) kW 0.0060 0.0070 0.0070 0.0080 0.0080 0.057 0.057 0.057 0.057 0.057 0.057
    Pck (Mod. riscaldatore carter) kW 0.00 0.00 0.00 0.00 0.00 0.055 0.055 0.055 0.055 0.055 0.055
    Controllo capacità 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
  Riscaldatore supplementare integrato Psup kW 3.00 3.00 3.00 9.00 3.00 3.00 9.00 9.00 3.00 3.00 9.00
    Emissioni di NOx mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Tipo di energia assorbita Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico Collegamento elettrico
Scambiatore di calore lato acqua Portata acqua Riscaldamento Nom. l/min 12.6 (5), 11.6 (6) 17.2 (5), 16.3 (6) 17.2 (5), 16.3 (6) 21.2 (5), 19.8 (6) 21.2 (5), 19.8 (6) 32.1 (7), 31.5 (8) 32.1 (7), 31.5 (8) 41.6 (7), 39.0 (8) 41.6 (7), 39.0 (8) 45.9 (7), 43.6 (8) 45.9 (7), 43.6 (8)
Pompa Unità prevalenza nominale Riscaldamento kPa 53.0 (5), 56.0 (6) 45.0 (5), 47.0 (6) 45.0 (5), 47.0 (6) 33.0 (5), 37.0 (6) 33.0 (5), 37.0 (6) 34.2 (7), 35.9 (8) 34.2 (7), 35.9 (8) 43.2 (7), 51.2 (8) 43.2 (7), 51.2 (8) 26.8 (7), 36.3 (8) 26.8 (7), 36.3 (8)
Risc. ambienti Uscita acqua climi rigidi 55°C Generale Capacità nominale -22°C kW 2.39 2.60 2.60 3.56 3.56 6.99 6.99 8.15 8.15 9.12 9.12
      Consumo energetico annuale kWh 2,133 2,306 2,306 3,088 3,088 6,740 6,740 7,870 7,870 8,580 8,580
      Efficienza stagionale riscaldamento ambienti % 107 107 107 110 110 95.0 95.0 95.5 95.5 98.3 98.3
      Consumo energetico annuale (valore calorifico lordo) Gj 7.68 8.30 8.30 11.1 11.1 24.3 24.3 28.3 28.3 30.9 30.9
  Uscita acqua cond. clim. medie 35°C Cond. A (-7°CBS/-8°CBU) PERd (Indice di energia primaria dichiarato) % 120 108 108 108 108 105 105 105 105 93.2 93.2
      Pdh (capacità dichiarata di risc.) kW 4.01 4.72 4.72 6.68 6.68 8.88 8.88 10.7 10.7 12.4 12.4
      Space heating-=-Average climate water outlet 35°C-=-A Condition (-7°CDB/-8°CWB)-=-Copd 3.01 2.69 2.69 2.69 2.69 2.63 2.63 2.63 2.63 2.33 2.33
    Condizione C (7°CBS/6°CBU) Pdh (capacità dichiarata di riscaldamento) kW 1.70 2.59 2.59 2.59 2.59 5.74 5.74 5.05 5.05 5.74 5.74
      PERd (Indice di energia primaria dichiarato) % 234 230 230 230 230 271 271 228 228 271 271
      Space heating-=-Average climate water outlet 35°C-=-C Condition (7°CDB/6°CWB)-=-Copd 0.980 0.980 0.980 1.00 1.00 0.940 0.940 1.00 1.00 0.940 0.940
    Cond. D (12°CBS/11°CBU) Pdh (capacità dichiarata di risc.) kW 39.2 2.61 2.61 2.61 2.61 6.50 6.50 5.16 5.16 6.50 6.50
      PERd (Indice di energia primaria dichiarato) % 308 291 291 291 291 359 359 268 268 359 359
      Space heating-=-Average climate water outlet 35°C-=-D Condition (12°CDB/11°CWB)-=-Copd 0.980 0.980 0.980 0.980 0.980 0.920 0.920 0.930 0.930 0.920 0.920
    Cond. G (-15°CBS/-) PERd (Indice di energia primaria dichiarato) % 0.00 0.00 0.00 0.00 0.00            
      Pdh (capacità dichiarata di risc.) kW 0.00 0.00 0.00 0.00 0.00            
      Space heating-=-Average climate water outlet 35°C-=-G Condition (-15°CDB/-)-=-Copd 0.00 0.00 0.00 0.00 0.00            
    Capac. suppl. potenzialità di risc. nom. Psup (alla Tdi progetto -10°C) kW 0.040 0.640 0.640 0.590 0.590 2.44 2.44 1.93 1.93 4.35 4.35
    Generale Consumo energetico annuale kWh 1,980 2,540 2,540 3,489 3,489 5,380 5,380 7,250 7,250 8,270 8,270
      Consumo energetico annuale (valore calorifico lordo) Gj 7.13 9.14 9.14 12.6 12.6 19.4 19.4 26.1 26.1 29.8 29.8
      Ƞs (Efficienza stagionale Risc. amb.) % 178 169 169 171 171 156 156 153 153 149 149
      Capacità nominale a -10°C kW 4.40 5.34 5.34 7.40 7.40 11.2 11.2 14.5 14.5 16.0 16.0
      Space heating-=-Average climate water outlet 35°C-=-General-=-Seasonal space heating eff class 4.52 4.29 4.29 4.34 4.34 3.98 3.98 3.90 3.90 3.80 3.80
    Cond. B (2°CBS/1°CBU) Pdh (capacità dichiarata di risc.) kW 2.40 3.90 3.90 3.90 3.90 6.03 6.03 7.71 7.71 8.62 8.62
      PERd (Indice di energia primaria dichiarato) % 176 170 170 170 170 162 162 163 163 150 150
      Space heating-=-Average climate water outlet 35°C-=-B Condition (2°CDB/1°CWB)-=-Copd 1.00 0.990 0.990 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (temperatura bivalente) Pdh (capacità dichiarata di risc.) kW 4.36 4.93 4.93 7.14 7.14 9.09 9.09 11.6 11.6 12.1 12.1
      PERd (Indice di energia primaria dichiarato) % 104 98.8 98.8 98.8 98.8 113 113 113 113 102 102
      Tbiv °C -10.0 -8.00 -8.00 -8.00 -8.00 -5.00 -5.00 -5.00 -5.00 -4.00 -4.00
      Space heating-=-Average climate water outlet 35°C-=-Tbiv (bivalent temperature)-=-Copd 2.61 2.47 2.47 2.47 2.47 2.82 2.82 2.83 2.83 2.56 2.56
    Tol (temp. lim. di es.) PERd (Indice di energia primaria dichiarato) % 104 91.6 91.6 91.6 91.6 93.6 93.6 104 104 82.0 82.0
      WTOL (Temp. limite di funz. risc. acqua) °C 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0
      Pdh (capacità dichiarata di risc.) kW 4.36 4.70 4.70 6.81 6.81 8.76 8.76 12.6 12.6 11.7 11.7
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      Space heating-=-Average climate water outlet 35°C-=-Tol (temperature operating limit)-=-Copd 2.61 2.29 2.29 2.29 2.29 2.34 2.34 2.60 2.60 2.05 2.05
  Uscita acqua climi caldi 55°C Generale Consumo energetico annuale (valore calorifico lordo) Gj 4.20 5.37 5.37 6.85 6.85 9.47 9.47 11.8 11.8 12.3 12.3
      Capacità nominale 2°C kW 4.27 5.30 5.30 6.59 6.59 7.58 7.58 9.84 9.84 10.3 10.3
      Ƞs (Efficienza stagionale riscaldamento ambienti) % 186 182 182 178 178 125 125 135 135 136 136
      Consumo energetico annuale kWh 1,168 1,491 1,491 1,904 1,904 2,630 2,630 3,270 3,270 3,420 3,420
  Uscita acqua climi rigidi 35°C Generale Qhe Consumi energetici annuali (Valore calorifico lordo) Gj           23.1 23.1 29.4 29.4 32.6 32.6
      Consumo energetico annuale kWh           6,430 6,430 8,170 8,170 9,050 9,050
      Ƞs (Efficienza stagionale riscaldamento ambienti) %           148 148 141 141 137 137
      Capacità nominale -22°C kW           10.3 10.3 12.3 12.3 13.3 13.3
  Uscita acqua climi caldi 35°C Generale Capacità nominale 2°C kW           9.06 9.06 10.9 10.9 11.4 11.4
      Ƞs (Efficienza stagionale riscaldamento ambienti) %           192 192 199 199 199 199
      Consumo energetico annuale kWh           1,950 1,950 2,350 2,350 2,480 2,480
      Consumo energetico annuale (valore calorifico lordo) Gj           7.02 7.02 8.46 8.46 8.92 8.92
  Uscita acqua condizioni climatiche medie 55°C Cond. A (-7°CBS/-8°CBU) PERd (Indice di energia primaria dichiarato) % 81.2 80.8 80.8 79.2 79.2 79.6 79.6 70.4 70.4 71.2 71.2
      Pdh (capacità dichiarata di risc.) kW 3.36 4.50 4.50 5.47 5.47 8.83 8.83 9.97 9.97 12.2 12.2
      Space heating-=-Average climate water outlet 55°C-=-A Condition (-7°CDB/-8°CWB)-=-Copd 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (temperatura bivalente) Tbiv °C -10.0 -9.00 -9.00 -10.0 -10.0 -7.00 -7.00 -6.00 -6.00 -7.00 -7.00
      Pdh (capacità dichiarata di risc.) kW 3.76 5.09 5.09 6.18 6.18 8.83 8.83 11.0 11.0 12.2 12.2
      PERd (Indice di energia primaria dichiarato) % 72.0 69.6 69.6 66.4 66.4 79.6 79.6 76.8 76.8 71.2 71.2
      Space heating-=-Average climate water outlet 55°C-=-Tbiv (bivalent temperature)-=-Copd 1.80 1.74 1.74 1.66 1.66 1.99 1.99 1.92 1.92 1.78 1.78
    Tol (temp. limite esercizio) TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      Pdh (capacità dichiarata di risc.) kW 3.76 4.62 4.62 6.18 6.18 9.08 9.08 12.2 12.2 13.3 13.3
      PERd (Indice di energia primaria dichiarato) % 72.0 69.6 69.6 66.4 66.4 71.6 71.6 70.0 70.0 68.4 68.4
      WTOL (Temp. lim. di funz. per risc. acqua) °C 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0
      Space heating-=-Average climate water outlet 55°C-=-Tol (temperature operating limit)-=-Copd 1.80 1.74 1.74 1.66 1.66 1.79 1.79 1.75 1.75 1.71 1.71
    Generale Consumo energetico annuale (valore calorifico lordo) Gj 8.48 12.1 12.1 14.6 14.6 22.6 22.6 28.4 28.4 32.3 32.3
      Efficienza stagionale risc. ambienti % 125 126 126 126 126 120 120 123 123 119 119
      Consumo energetico annuale kWh 2,356 3,369 3,369 4,064 4,064 6,260 6,260 7,900 7,900 8,970 8,970
      Capacità nominale -10°C kW 3.70 5.30 5.30 6.40 6.40 9.99 9.99 12.7 12.7 13.9 13.9
      Space heating-=-Average climate water outlet 55°C-=-General-=-Seasonal space heating eff class 3.20 3.22 3.22 3.23 3.23 3.09 3.09 3.16 3.16 3.06 3.06
    Condizione B (2°CBS/1°CBU) Pdh (capacità dichiarata di riscaldamento) kW 2.00 4.43 4.43 3.43 3.43 5.28 5.28 6.76 6.76 7.61 7.61
      PERd (Indice di energia primaria dichiarato) % 123 127 127 127 127 130 130 142 142 125 125
      Space heating-=-Average climate water outlet 55°C-=-B Condition (2°CDB/1°CWB)-=-Copd 1.00 0.990 0.990 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Cond. C (7°CBS/6°CBU) Pdh (capacità dichiarata di risc.) kW 2.77 3.51 3.51 3.50 3.50 4.47 4.47 4.66 4.66 4.83 4.83
      PERd (Indice di energia primaria dichiarato) % 171 168 168 168 168 172 172 169 169 176 176
      Space heating-=-Average climate water outlet 55°C-=-C Condition (7°CDB/6°CWB)-=-Copd 0.990 0.990 0.990 0.990 0.990 0.950 0.950 0.950 0.950 1.00 1.00
    Condizione D (12°CBS/11°CBU) PERd (Indice di energia primaria dichiarato) % 253 233 233 233 233 256 256 218 218 254 254
      Pdh (capacità dichiarata di riscaldamento) kW 2.65 3.28 3.28 3.28 3.28 5.37 5.37 5.26 5.26 5.38 5.38
      Space heating-=-Average climate water outlet 55°C-=-D Condition (12°CDB/11°CWB)-=-Copd 0.990 0.990 0.990 0.990 0.990 0.930 0.930 0.940 0.940 0.930 0.930
    Cap. suppl. potenz. di risc. nominale Psup (alla Tdi progetto -10°C) kW 0.00 0.680 0.680 0.220 0.220 0.910 0.910 0.550 0.550 0.580 0.580
Capacità di riscaldamento Nom. kW 4.40 (1), 4.03 (2) 6.00 (1), 5.67 (2) 6.00 (1), 5.67 (2) 7.40 (1), 6.89 (2) 7.40 (1), 6.89 (2) 11.2 (1), 11.0 (2) 11.2 (1), 11.0 (2) 14.5 (1), 13.6 (2) 14.5 (1), 13.6 (2) 16.0 (1), 15.2 (2) 16.0 (1), 15.2 (2)
  Min. kW 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1)            
  Max. kW 5.12 (1), 4.90 (2) 8.35 (1), 7.95 (2) 8.35 (1), 7.95 (2) 10.0 (1), 9.53 (2) 10.0 (1), 9.53 (2) 8.60 (3), 8.60 (4) 8.60 (3), 8.60 (4) 10.6 (3), 10.8 (4) 10.6 (3), 10.8 (4) 11.4 (3), 10.9 (4) 11.4 (3), 10.9 (4)
Generale LW(A) Livello di potenza sonora (conforme alla direttiva EN14825) Interno dB(A) 42.0 42.0 42.0 42.0 42.0 42.0 42.0 44.0 44.0 44.0 44.0
  Dati Fornitore/Costruttore Nome e indirizzo Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Descrizione prodotto General-=-Product description-=-Low temperature heat pump Sì Sì Sì Sì Sì Sì Sì Sì Sì Sì Sì
LW(A) Livello di potenza sonora (conforme alla direttiva EN14825) Esterno dB(A) 61.0 62.0 62.0 62.0 62.0 64.0 64.0 64.0 64.0 66.0 66.0
Potenza assorbita Riscaldamento Max. kW           3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
    Nom. kW 0.870 (1), 1.13 (2) 1.27 (1), 1.59 (2) 1.27 (1), 1.59 (2) 1.66 (1), 2.01 (2) 1.66 (1), 2.01 (2) 2.43 (1), 3.10 (2) 2.43 (1), 3.10 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
Sound condition ecodesign and energy label 5.04 (1), 3.58 (2) 4.74 (1), 3.56 (2) 4.74 (1), 3.56 (2) 4.45 (1), 3.42 (2) 4.45 (1), 3.42 (2) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4)
Note Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condizione 1: raffreddamento Ta 35°C - LWE 18°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condizione 2: raffreddamento Ta 35°C - LWE 7°C (DT = 5°C); riscaldamento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C)
  T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) Condizione 3: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 35°C Condizione 3: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 35°C Condizione 3: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 35°C Condizione 3: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 35°C Condizione 3: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 35°C Condizione 3: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 35°C
  T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) Condizione 4: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 45℃ Condizione 4: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 45℃ Condizione 4: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 45℃ Condizione 4: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 45℃ Condizione 4: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 45℃ Condizione 4: riscaldamento Ta BS -7°C (UR 85%) - Acqua in uscita condensatore 45℃
  BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C) T. est. 35°C – LWE 7°C (DT=5°C)
  BS/BU 7°C/6°C - LWC 45°C (Dt=5°C) BS/BU 7°C/6°C - LWC 45°C (Dt=5°C) BS/BU 7°C/6°C - LWC 45°C (Dt=5°C) BS/BU 7°C/6°C - LWC 45°C (Dt=5°C) BS/BU 7°C/6°C - LWC 45°C (Dt=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C) T. est. 35°C – Acqua uscita evaporatore 18°C (DT=5°C)
  Contiene gas fluorurati a effetto serra Contiene gas fluorurati a effetto serra Contiene gas fluorurati a effetto serra Contiene gas fluorurati a effetto serra Contiene gas fluorurati a effetto serra BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C) BS/BU 7°C/6°C-Acqua in uscita condensatore 35°C(DT=5°C)