FBQ35C8VEB / RXS35L3V1B
Poff (Modo spento) W 14.0
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 3.50
    Consumo energetico annuale kWh 205
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.97
    Condizione D (20°C - 27/19) Pdc kW 1.70
      potenza assorbita kW 0.16
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.92
    Condizione C (25°C - 27/19) potenza assorbita kW 0.20
      Pdc kW 1.66
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.26
    Condizione A (35°C - 27/19) potenza assorbita kW 0.95
      Pdc kW 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.70
    Condizione B (30°C - 27/19) Pdc kW 2.58
      potenza assorbita kW 0.47
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.48
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 1,033
    Pdesign kW 2.90
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.51
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+
    TBivalent Pdh (capacità dichiarata di risc.) kW 2.57
      Potenza assorbita kW 1.07
      Tbiv (temp. bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.41
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.02
      Potenza assorbita kW 0.21
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.78
    TOL Tol (temperatura limite di esercizio) °C -15
      Pdh (capacità dichiarata di risc.) kW 2.12
      Potenza assorbita kW 1.09
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.95
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 2.57
      Potenza assorbita kW 1.07
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.41
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 1.19
      Potenza assorbita kW 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.31
    Cond. B (2°C) Potenza assorbita kW 0.38
      Pdh (capacità dichiarata di risc.) kW 1.57
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.09
Capacità di Raffrescamento Nom. Btu/ora 11,590 (2)
  Min. kW 1.4
  Nom. Kcal/ora 2,920 (2)
  Max. kW 3.9
  Min. Kcal/ora 1,200
  Min. Btu/ora 4,770
  Nom. kW 3.40 (2)
  Max. Btu/ora 13,300
  Max. Kcal/ora 3,350
Pck (Modo riscaldamento del carter) W 0.0
Efficienza nominale Consumo energetico annuale kWh 459 (0.000)
  Classe energetica Riscaldamento A
  Nominal efficiency-=-Cop 3.70
Riscaldamento Heating-=-Heating cdh degradation heating 0.25
Collegamenti tubazioni Liquid DE mm 6.35
  Gas DE mm 9.5
  Scarico DE mm VP25 (Diametro esterno 32, Diametro interno 25)
  Isolamento termico Sulla linea del liquido e su quella del gas
Capacità di riscaldamento Min. Btu/ora 4,430
  Nom. Btu/ora 13,640 (2)
  Max. Kcal/ora 4,300
  Max. Btu/ora 17,050
  Nom. kW 4.00 (2)
  Min. kW 1.3
  Nom. Kcal/ora 3,440 (2)
  Min. Kcal/ora 1,120
  Max. kW 5.0
Pto (Thermostat off) W 7.0
Potenza assorbita Raffrescamento Min. kW 0.490
    Nom. kW 0.918 (2)
    Max. kW 1.490
  Riscaldamento Max. kW 1.760
    Min. kW 0.270
    Nom. kW 1.110 (2)
Unità interna Sì
Current Corrente di funzionamento nominale - 50Hz Riscaldamento A 5.20 (3), 5.00 (4), 4.80 (5)
    Raffrescamento A 4.16 (3), 3.98 (4), 3.81 (5)
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale
  220V
  230V
  240V