FCQG35FVEB / RXL35K2V1B FCQG50FVEB / RXL50K2V1B
Poff (Modo spento) W 14.0 15.0
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 14.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 3.50 5.00
    Consumo energetico annuale kWh 217 286
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.65 6.11
    Condizione D (20°C - 27/19) Pdc kW 1.84 2.25
      potenza assorbita kW 0.17 0.19
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.89 11.74
    Condizione C (25°C - 27/19) potenza assorbita kW 0.20 0.27
      Pdc kW 1.75 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.54 8.65
    Condizione A (35°C - 27/19) potenza assorbita kW 0.94 1.36
      Pdc kW 3.50 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.71 3.67
    Condizione B (30°C - 27/19) Pdc kW 2.58 3.67
      potenza assorbita kW 0.44 0.64
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.81 5.76
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 1,001 1,463
    Pdesign kW 3.32 4.36
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.62 0.83
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++ A+
    TBivalent Pdh (capacità dichiarata di risc.) kW 2.94 3.86
      Potenza assorbita kW 1.17 1.67
      Tbiv (temp. bivalente) °C -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.52 2.31
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.47 1.54
      Potenza assorbita kW 0.23 0.29
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.29 5.37
    TOL Tol (temperatura limite di esercizio) °C -25 -25
      Pdh (capacità dichiarata di risc.) kW 1.50 1.87
      Potenza assorbita kW 1.02 1.44
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.47 1.30
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 2.94 3.86
      Potenza assorbita kW 1.17 1.67
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.52 2.31
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 1.72 1.79
      Potenza assorbita kW 0.23 0.27
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.59 6.71
    Cond. B (2°C) Potenza assorbita kW 0.35 0.52
      Pdh (capacità dichiarata di risc.) kW 1.79 2.34
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.09 4.48
Capacità di Raffrescamento Nom. Btu/ora 11,590 17,050
  Min. kW 1.3 1.6
  Nom. Kcal/ora 2,920 4,300
  Max. kW 4.0 5.7
  Min. Kcal/ora 1,120 1,370
  Min. Btu/ora 4,430 5,450
  Nom. kW 3.40 5.00
  Max. Btu/ora 13,640 19,430
  Max. Kcal/ora 3,440 4,900
Pck (Modo riscaldamento del carter) W 0.0 0.0
Efficienza nominale Consumo energetico annuale kWh 460 (0.000) 700 (0.000)
  Classe energetica Riscaldamento A A
  Nominal efficiency-=-Cop 3.70 3.57
Riscaldamento Heating-=-Heating cdh degradation heating 0.25 0.25
Capacità di riscaldamento Min. Btu/ora 4,430 5,450
  Nom. Btu/ora 14,320 20,460
  Max. Kcal/ora 4,470 5,590
  Max. Btu/ora 17,730 22,160
  Nom. kW 4.20 6.00
  Min. kW 1.3 1.6
  Nom. Kcal/ora 3,610 5,160
  Min. Kcal/ora 1,120 1,370
  Max. kW 5.2 6.5
Pto (Thermostat off) W 80.0 80.0
Potenza assorbita Raffrescamento Min. kW 0.400 0.530
    Nom. kW 0.920 1.400
    Max. kW 1.100 1.980
  Riscaldamento Max. kW 1.840 3.530
    Min. kW 0.230 0.290
    Nom. kW 1.180 1.550
Stagione fredda inclusa Sì Sì
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale