FCQG60FVEB / RXS60F4V1B FCQG60FVEB / RXS60F3V1B
Poff (Modo spento) W 20.0  
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 20.0  
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 5.70  
    Consumo energetico annuale kWh 347  
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.74  
    Condizione D (20°C - 27/19) Pdc kW 2.35  
      potenza assorbita kW 0.20  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.44  
    Condizione C (25°C - 27/19) potenza assorbita kW 0.33  
      Pdc kW 2.69  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.05  
    Condizione A (35°C - 27/19) potenza assorbita kW 1.69  
      Pdc kW 5.70  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.37  
    Condizione B (30°C - 27/19) Pdc kW 4.20  
      potenza assorbita kW 0.79  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.34  
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 1,704  
    Pdesign kW 4.71  
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.94  
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A  
    TBivalent Pdh (capacità dichiarata di risc.) kW 4.17  
      Potenza assorbita kW 2.01  
      Tbiv (temp. bivalente) °C -7  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.07  
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.64  
      Potenza assorbita kW 0.33  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.92  
    TOL Tol (temperatura limite di esercizio) °C -15  
      Pdh (capacità dichiarata di risc.) kW 3.09  
      Potenza assorbita kW 1.88  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.64  
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 4.17  
      Potenza assorbita kW 2.01  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.07  
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 1.81  
      Potenza assorbita kW 0.29  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.21  
    Cond. B (2°C) Potenza assorbita kW 0.60  
      Pdh (capacità dichiarata di risc.) kW 2.53  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.21  
Capacità di Raffrescamento Nom. kW 5.70 5.70 (3)
Pck (Modo riscaldamento del carter) W 0.0  
Efficienza nominale Consumo energetico annuale kWh 820 (0.000) 820 (0.000)
  Classe energetica Riscaldamento A A
  Nominal efficiency-=-Cop 3.48 3.48
Riscaldamento Psb (Consumo di energia in modo attesa - riscaldamento) W 20.0  
Collegamenti tubazioni Liquid DE mm 6.35  
  Gas DE mm 12.7  
  Scarico DE mm VP20 (Diametro esterno 26, Diametro interno 20)  
  Isolamento termico Sulla linea del liquido e su quella del gas  
Capacità di riscaldamento Nom. kW 7.00 7.00 (4)
Pto (Thermostat off) W 80.0  
Potenza assorbita Raffrescamento Nom. kW 1.64 1.64
  Riscaldamento Nom. kW 1.99 1.99
Stagione fredda inclusa Sì  
Current Corrente di funzionamento nominale - 50Hz Raffrescamento A 9.6  
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Classe energetica: dalla classe A (più efficiente) alla classe G (meno efficiente)
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Consumo energetico annuale: sulla base di un consumo medio di 500 ore di esercizio all'anno a pieno carico (condizioni nominali)
    Raffreddamento: temp. interna 27°CBS, 19,0°CBU / temp. esterna 35°CBS; lunghezza equivalente delle tubazioni: 5m; dislivello: 0m
    Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m; dislivello: 0m
    Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale