FCQG71FVEB / RZQSG71L2V1B FCQG100FVEB / RZQSG100L7Y1B FCQG100FVEB / RZQSG100L7V1B FCQG100FVEB / RZQSG100L7Y1B9 FCQG125FVEB / RZQSG125L7Y1B FCQG125FVEB / RZQSG125L7V1B FCQG125FVEB / RZQSG125L7Y1B9
Poff (Modo spento) W 0.0   0.0 0.0   0.0 0.0
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 7.0   7.0 7.0   7.0 7.0
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25 0.25   0.25 0.25
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 6.80   9.50 9.50   12.00 12.00
    Consumo energetico annuale kWh 466   650.685 650.685   821.918 821.918
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.11 5.11 (6) 5.11 5.11 5.11 (6) 5.11 5.11
    Condizione D (20°C - 27/19) Pdc kW 3.63   3.99 3.99   3.98 3.98
      potenza assorbita kW 0.42   0.49 0.48   0.40 0.40
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 8.62   8.10 8.27   10.05 10.04
    Condizione C (25°C - 27/19) potenza assorbita kW 0.56   0.78 0.77   0.84 0.84
      Pdc kW 3.51   4.56 4.56   5.69 5.69
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 6.28   5.81 5.90   6.81 6.77
    Condizione A (35°C - 27/19) potenza assorbita kW 2.19   2.88 2.88   4.12 4.12
      Pdc kW 6.80   9.50 9.50   12.00 12.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.10   3.30 3.30   2.91 2.91
    Condizione B (30°C - 27/19) Pdc kW 5.01   7.00 7.00   8.84 8.84
      potenza assorbita kW 1.27   1.53 1.59   2.86 2.83
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 3.94   4.58 4.40   3.10 3.12
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 2,327   2,799 2,799   2,949 2,949
    Pdesign kW 6.33   7.60 7.60   8.03 8.03
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.58   0.53 0.53   0.73 0.69
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A 3.80 (6) A A 3.81 (6) A A
    TBivalent Pdh (capacità dichiarata di risc.) kW 5.60   6.72 6.72   7.10 7.10
      Potenza assorbita kW     2.09 2.10   2.41 2.43
      Tbiv (temp. bivalente) °C -7   -7 -7   -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.25   3.21 3.20   2.94 2.93
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 2.89   3.06 3.05   3.07 3.07
      Potenza assorbita kW     0.56 0.56   0.55 0.56
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.85   5.45 5.50   5.54 5.52
    TOL Tol (temperatura limite di esercizio) °C -15   -15 -15   -15 -15
      Pdh (capacità dichiarata di risc.) kW 6.00   7.66 7.66   7.64 7.74
      Potenza assorbita kW 3.24   3.70 3.83   3.65 3.69
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.85   2.07 2.03   2.09 2.10
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 5.60   6.72 6.72   7.10 7.10
      Potenza assorbita kW     2.09 2.10   2.41 2.43
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.25   3.21 3.20   2.94 2.93
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 3.28   3.49 3.49   3.50 3.50
      Potenza assorbita kW     0.54 0.54   0.54 0.54
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.73   6.43 6.48   6.53 6.50
    Cond. B (2°C) Potenza assorbita kW     1.48 1.48   1.46 1.45
      Pdh (capacità dichiarata di risc.) kW 4.06   5.07 5.07   5.07 5.07
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.82   3.43 3.41   3.47 3.49
Capacità di Raffrescamento Nom. kW 6.8 9.5 (3) 9.5 9.5 12.0 (3) 12.0 12.0
Pck (Modo riscaldamento del carter) W 0.0   0.0 0.0   0.0 0.0
Efficienza nominale Consumo energetico annuale kWh 971 (0.000) 1,440 (0.000) 1,440 (0.000) 1,440 (0.000) 1,870 (0.000) 1,870 (0.000) 1,870 (0.000)
  Classe energetica Riscaldamento A A A A A A A
  Nominal efficiency-=-Cop 3.21 3.30 3.30 3.30 3.21 3.21 3.21
Riscaldamento Psb (Consumo di energia in modo attesa - riscaldamento) W     14.0 14.0   14.0 14.0
  Heating-=-Heating cdh degradation heating 0.25   0.25 0.25   0.25 0.25
Capacità di riscaldamento Nom. kW 7.5 10.8 (4) 10.8 10.8 13.5 (4) 13.5 13.5
Pto (Thermostat off) W 34.0   109.0 109.0   97.0 97.0
Potenza assorbita Raffrescamento Nom. kW   2.88     3.74    
  Riscaldamento Nom. kW   3.05     3.96    
Stagione fredda inclusa Sì   Sì Sì   Sì Sì
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Consumo energetico annuale: sulla base di un consumo medio di 500 ore di esercizio all'anno a pieno carico (condizioni nominali) Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Consumo energetico annuale: sulla base di un consumo medio di 500 ore di esercizio all'anno a pieno carico (condizioni nominali) Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Classe energetica: dalla classe A (più efficiente) alla classe G (meno efficiente) Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Classe energetica: dalla classe A (più efficiente) alla classe G (meno efficiente) Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale
    Raffreddamento: temp. interna 27°CBS, 19°CBU, temp. esterna 35°CBS; lunghezza equivalente delle tubazioni: 5m; dislivello: 0m     Raffreddamento: temp. interna 27°CBS, 19°CBU, temp. esterna 35°CBS; lunghezza equivalente delle tubazioni: 5m; dislivello: 0m    
    Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m; dislivello: 0m     Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m; dislivello: 0m    
    Il consumo energetico annuale è conforme alla direttiva 2002/31/CE sulla classificazione energetica     Il consumo energetico annuale è conforme alla direttiva 2002/31/CE sulla classificazione energetica    
    I valori SEER e SCOP sono conformi alla norma europea EN 14825     I valori SEER e SCOP sono conformi alla norma europea EN 14825    
    Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale     Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale