FLXS25BAVMB / RXS25L2V1B FLXS50BAVMB / RXS50L2V1B
Poff (Modo spento) W 14.0 15.0
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 14.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 2.50 4.90
    Consumo energetico annuale kWh 169 326
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.19 5.25
    Condizione D (20°C - 27/19) Pdc kW 1.44 2.11
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.56 10.04
    Condizione C (25°C - 27/19) Pdc kW 1.36 2.32
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.40 7.19
    Condizione A (35°C - 27/19) Pdc kW 2.50 4.90
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.74 3.08
    Condizione B (30°C - 27/19) Pdc kW 1.84 3.61
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.96 4.78
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 921 1,546
    Pdesign kW 2.50 4.20
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.33 0.37
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A A
    TBivalent Pdh (capacità dichiarata di risc.) kW 2.21 3.72
      Tbiv (temp. bivalente) °C -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.33 2.27
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.10 1.59
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.94 4.76
    TOL Tol (temperatura limite di esercizio) °C -15 -15
      Pdh (capacità dichiarata di risc.) kW 2.10 4.03
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.92 1.82
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 2.21 3.72
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.33 2.27
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 1.28 1.86
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.25 5.96
    Cond. B (2°C) Pdh (capacità dichiarata di risc.) kW 1.35 2.26
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.02 4.01
Capacità di Raffrescamento Nom. Btu/ora 8,500 16,730
  Min. kW 1.2 0.9
  Nom. Kcal/ora 2,150 4,210
  Max. kW 3.0 5.3
  Min. Kcal/ora 1,030 770
  Min. Btu/ora 4,100 3,070
  Nom. kW 2.5 4.9
  Max. Btu/ora 10,200 18,090
  Max. Kcal/ora 2,580 4,560
Pck (Modo riscaldamento del carter) W 0.0 0.0
Efficienza nominale Consumo energetico annuale kWh 325 (0.000) 860 (0.000)
  Classe energetica Riscaldamento A C
  Nominal efficiency-=-Cop 3.85 2.85
Riscaldamento Heating-=-Heating cdh degradation heating 0.25 0.25
Collegamenti tubazioni Liquido DE mm 6.35 6.35
  Gas DE mm 9.5 12.7
  Scarico DE mm 18.0 20
  Isolamento termico Sulla linea del liquido e su quella del gas Sulla linea del liquido e su quella del gas
Capacità di riscaldamento Min. Btu/ora 4,100 3,070
  Nom. Btu/ora 11,600 20,830
  Max. Kcal/ora 3,870 6,450
  Max. Btu/ora 15,400 18,090
  Nom. kW 3.4 6.1
  Min. kW 1.2 0.9
  Nom. Kcal/ora 2,920 5,250
  Min. Kcal/ora 1,030 770
  Max. kW 4.5 7.5
Pto (Thermostat off) W 70.0 80.0
Potenza assorbita Raffrescamento Min. kW 0.300 0.450
    Nom. kW 0.650 1.720
    Max. kW 0.860 1.950
  Riscaldamento Max. kW 1.490 3.540
    Min. kW 0.290 0.310
    Nom. kW 0.960 1.820
Stagione fredda inclusa Sì Sì
Corrente Corrente di funzionamento nominale - 50Hz Riscaldamento A 4.7 (2), 4.5 (3), 4.3 (4) 8.4 (2), 8.0 (3), 7.7 (4)
    Raffrescamento A 3.7 (2), 3.6 (3), 3.4 (4) 8.0 (2), 7.6 (3), 7.3 (4)
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE
  220V 220V
  230V 230V
  240V 240V
  Raffreddamento: temp. interna 27°CBS, 19,0°CBU / temp. esterna 35°CBS, 24°CBU; lunghezza equivalente delle tubazioni: 5m Raffreddamento: temp. interna 27°CBS, 19,0°CBU / temp. esterna 35°CBS, 24°CBU; lunghezza equivalente delle tubazioni: 5m
  Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale