FLXS25BAVMB / RXS25L3V1B
Poff (Modo spento) W 14.0
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Deumidificazione Raffrescamento l/ora 1.2
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 2.50
    Consumo energetico annuale kWh 169
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.19
    Condizione D (20°C - 27/19) Pdc kW 1.44
      potenza assorbita kW 0.14
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.56
    Condizione C (25°C - 27/19) potenza assorbita kW 0.16
      Pdc kW 1.36
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.40
    Condizione A (35°C - 27/19) potenza assorbita kW 0.67
      Pdc kW 2.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.74
    Condizione B (30°C - 27/19) Pdc kW 1.84
      potenza assorbita kW 0.31
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.96
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 921
    Pdesign kW 2.50
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.33
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A
    TBivalent Pdh (capacità dichiarata di risc.) kW 2.21
      Potenza assorbita kW 0.95
      Tbiv (temp. bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.33
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.10
      Potenza assorbita kW 0.22
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.94
    TOL Tol (temperatura limite di esercizio) °C -15
      Pdh (capacità dichiarata di risc.) kW 2.10
      Potenza assorbita kW 1.09
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.92
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 2.21
      Potenza assorbita kW 0.95
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.33
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 1.28
      Potenza assorbita kW 0.20
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.25
    Cond. B (2°C) Potenza assorbita kW 0.34
      Pdh (capacità dichiarata di risc.) kW 1.35
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.02
Capacità di Raffrescamento Nom. Btu/ora 8,500 (2)
  Min. kW 1.2
  Nom. Kcal/ora 2,150 (2)
  Max. kW 3.0
  Min. Kcal/ora 1,030
  Min. Btu/ora 4,100
  Nom. kW 2.5 (2)
  Max. Btu/ora 10,200
  Max. Kcal/ora 2,580
Pck (Modo riscaldamento del carter) W 0.0
Efficienza nominale Consumo energetico annuale kWh 334 (0.000)
  Classe energetica Riscaldamento A
  Nominal efficiency-=-Cop 3.74 (1)
Riscaldamento Heating-=-Heating cdh degradation heating 0.25
Collegamenti tubazioni Liquid DE mm 6.35
  Gas DE mm 9.5
  Scarico DE mm 18.0
  Isolamento termico Sulla linea del liquido e su quella del gas
Capacità di riscaldamento Min. Btu/ora 4,100
  Nom. Btu/ora 11,600 (2)
  Max. Kcal/ora 3,870
  Max. Btu/ora 15,400
  Nom. kW 3.4 (2)
  Min. kW 1.2
  Nom. Kcal/ora 2,920 (2)
  Min. Kcal/ora 1,030
  Max. kW 4.5
Pto (Thermostat off) W 70.0
Potenza assorbita Raffrescamento Min. kW 0.300
    Nom. kW 0.668 (2)
    Max. kW 0.860
  Riscaldamento Max. kW 1.490
    Min. kW 0.290
    Nom. kW 0.960 (2)
Unità interna Sì
Current Corrente di funzionamento nominale - 50Hz Riscaldamento A 4.70 (3), 4.50 (4), 4.30 (5)
    Raffrescamento A 3.80 (3), 3.70 (4), 3.49 (5)
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale
  220V
  230V
  240V