FLXS35BAVMB9 / RXS35L2V1B |
Poff (Modo spento) |
W |
14.0 |
Raffrescamento |
Psb (Consumo di energia in modo attesa - raffrescamento) |
W |
14.0 |
|
Cooling-=-Cooling cdc degradation cooling |
0.25 |
Eff. stagionale (secondo EN14825) |
Raffrescamento |
Pdesign |
kW |
3.50 |
|
|
Consumo energetico annuale |
kWh |
252 |
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class |
4.87 |
|
|
Condizione D (20°C - 27/19) |
Pdc |
kW |
1.42 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd |
9.91 |
|
|
Condizione C (25°C - 27/19) |
Pdc |
kW |
1.66 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd |
6.90 |
|
|
Condizione A (35°C - 27/19) |
Pdc |
kW |
3.50 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd |
2.88 |
|
|
Condizione B (30°C - 27/19) |
Pdc |
kW |
2.58 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd |
4.59 |
|
Risc. (Condizioni clim. medie) |
Consumo energetico annuale |
kWh |
1,068 |
|
|
Pdesign |
kW |
2.90 |
|
|
Richiesta cap. di risc. di riserva alle cond. di prog. |
kW |
0.45 |
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a |
A |
|
|
TBivalent |
Pdh (capacità dichiarata di risc.) |
kW |
2.57 |
|
|
|
Tbiv (temp. bivalente) |
°C |
-7 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop |
2.30 |
|
|
Cond. C (7°C) |
Pdh (capacità dichiarata di risc.) |
kW |
1.05 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop |
4.81 |
|
|
TOL |
Tol (temperatura limite di esercizio) |
°C |
-15 |
|
|
|
Pdh (capacità dichiarata di risc.) |
kW |
2.25 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop |
1.90 |
|
|
Cond. A (-7°C) |
Pdh (capacità dichiarata di risc.) |
kW |
2.57 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop |
2.30 |
|
|
Cond. D (12°C) |
Pdh (capacità dichiarata di risc.) |
kW |
1.23 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop |
6.22 |
|
|
Cond. B (2°C) |
Pdh (capacità dichiarata di risc.) |
kW |
1.56 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop |
3.98 |
Capacità di Raffrescamento |
Nom. |
Btu/ora |
11,900 |
|
Min. |
kW |
1.2 |
|
Nom. |
Kcal/ora |
3,010 |
|
Max. |
kW |
3.8 |
|
Min. |
Kcal/ora |
1,030 |
|
Min. |
Btu/ora |
4,100 |
|
Nom. |
kW |
3.5 |
|
Max. |
Btu/ora |
13,000 |
|
Max. |
Kcal/ora |
3,270 |
Pck (Modo riscaldamento del carter) |
W |
0.0 |
Efficienza nominale |
Consumo energetico annuale |
kWh |
565 (0.000) |
|
Classe energetica |
Riscaldamento |
B |
|
Nominal efficiency-=-Cop |
3.10 |
Riscaldamento |
Heating-=-Heating cdh degradation heating |
0.25 |
Collegamenti tubazioni |
Liquid |
DE |
mm |
6.35 |
|
Gas |
DE |
mm |
9.5 |
|
Scarico |
DE |
mm |
18.0 |
|
Isolamento termico |
Sulla linea del liquido e su quella del gas |
Capacità di riscaldamento |
Min. |
Btu/ora |
4,100 |
|
Nom. |
Btu/ora |
13,600 |
|
Max. |
Kcal/ora |
4,300 |
|
Max. |
Btu/ora |
17,100 |
|
Nom. |
kW |
4.0 |
|
Min. |
kW |
1.4 |
|
Nom. |
Kcal/ora |
3,440 |
|
Min. |
Kcal/ora |
1,030 |
|
Max. |
kW |
5.0 |
Pto (Thermostat off) |
W |
75.0 |
Potenza assorbita |
Raffrescamento |
Min. |
kW |
0.300 |
|
|
Nom. |
kW |
1.130 |
|
|
Max. |
kW |
1.260 |
|
Riscaldamento |
Max. |
kW |
1.850 |
|
|
Min. |
kW |
0.290 |
|
|
Nom. |
kW |
1.120 |
Stagione fredda inclusa |
Sì |
Current |
Corrente di funzionamento nominale - 50Hz |
Riscaldamento |
A |
5.6 (2), 5.3 (3), 5.1 (4) |
|
|
Raffrescamento |
A |
5.3 (2), 5.1 (3), 4.9 (4) |
Note |
Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE |
|
220V |
|
230V |
|
240V |
|
Raffreddamento: temp. interna 27°CBS, 19,0°CBU / temp. esterna 35°CBS, 24°CBU; lunghezza equivalente delle tubazioni: 5m |
|
Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m |
|
Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale |