Specifiche Tecniche FTX-GV / RX-GVB

FTX60GV1B / RX60G4V1B FTX71GV1B / RX71GV1B8
Poff (Modo spento) W 15.0 20.0
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 15.0 20.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 6.00 7.10
    Consumo energetico annuale kWh 391 500
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.37 4.97
    Condizione D (20°C - 27/19) Pdc kW 2.25 3.10
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.00 9.48
    Condizione C (25°C - 27/19) Pdc kW 2.84 3.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 6.74 6.87
    Condizione A (35°C - 27/19) Pdc kW 6.00 7.10
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 2.81 2.90
    Condizione B (30°C - 27/19) Pdc kW 4.42 5.24
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.48 4.57
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 1,730 2,276
    Pdesign kW 4.80 6.20
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.76 0.83
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A A
    TBivalent Pdh (capacità dichiarata di risc.) kW 4.25 5.48
      Tbiv (temp. bivalente) °C -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.21 2.26
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.66 2.28
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.91 4.85
    TOL Tol (temperatura limite di esercizio) °C -15 -15
      Pdh (capacità dichiarata di risc.) kW 3.69 5.18
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.81 1.77
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 4.25 5.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.21 2.26
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 1.95 2.60
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.12 5.20
    Cond. B (2°C) Pdh (capacità dichiarata di risc.) kW 2.58 3.34
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.11 4.05
Capacità di Raffrescamento Nom. Btu/ora 20,500 (2) 24,200 (2)
  Min. kW 1.7 (2) 2.3 (2)
  Nom. Kcal/ora 5,160 (2) 6,110 (2)
  Max. kW 6.7 (2) 8.5 (2)
  Min. Kcal/ora 1,460 (2) 1,980 (2)
  Min. Btu/ora 5,800 (2) 7,800 (2)
  Nom. kW 6.0 (2) 7.10 (2)
  Max. Btu/ora 22,900 (2) 29,000 (2)
  Max. Kcal/ora 5,760 (2) 7,310 (2)
Pck (Modo riscaldamento del carter) W 0.0 10.0
Efficienza nominale Annual energy consumption kWh 995 (0.000) 1,175 (0.000)
  Classe energetica Riscaldamento B B
  Nominal efficiency-=-Cop 3.02 (1) 3.02 (1)
Riscaldamento Heating-=-Heating cdh degradation heating 0.25 0.25
Collegamenti tubazioni Liquid DE mm 6.35 6.35
  Gas DE mm 12.7 15.9
  Scarico DE mm 18 18
Capacità di riscaldamento Min. Btu/ora 5,800 (3) 7,800 (3)
  Nom. Btu/ora 23,900 (3) 28,000 (3)
  Max. Kcal/ora 6,880 (3) 8,770 (3)
  Max. Btu/ora 27,300 (3) 34,800 (3)
  Nom. kW 7.0 (3) 8.20 (3)
  Min. kW 1.7 (3) 2.3 (3)
  Nom. Kcal/ora 6,020 (3) 7,050 (3)
  Min. Kcal/ora 1,460 (3) 1,980 (3)
  Max. kW 8.0 (3) 10.2 (3)
Pto (Thermostat off) W 42.0 42.0
Potenza assorbita Raffrescamento Min. kW 0.440 (2) 0.570 (2)
    Nom. kW 1.990 (2) 2.350 (2)
    Max. kW 2.400 (2) 3.200 (2)
  Riscaldamento Max. kW 2.810 (3) 3.820 (3)
    Min. kW 0.400 (3) 0.520 (3)
    Nom. kW 2.040 (3) 2.550 (3)
Stagione fredda inclusa Sì Sì
Corrente Corrente di funzionamento nominale - 50Hz Riscaldamento A 9.4 (4), 9.0 (5), 8.6 (6) 11.7 (4), 11.2 (5), 10.7 (6)
    Raffrescamento A 9.2 (4), 8.8 (5), 8.4 (6) 10.8 (4), 10.4 (5), 9.9 (6)
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE
  Raffreddamento: temp. interna 27°CBS, 19°CBU, temp. esterna 35°CBS, 24°CBU; lunghezza equivalente delle tubazioni: 5m Raffreddamento: temp. interna 27°CBS, 19°CBU, temp. esterna 35°CBS, 24°CBU; lunghezza equivalente delle tubazioni: 5m
  Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU; lunghezza equivalente del circuito frigorifero: 5m
  220V 220V
  230V 230V
  240V 240V
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale