FTXZ25NV1B / RXZ25NV1B FTXZ35NV1B / RXZ35NV1B FTXZ50NV1B / RXZ50NV1B
Poff (Modo spento) W 1.0 1.0 1.0
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 2.50 3.50 5.00
    Consumo energetico annuale kWh 92 136 203
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 9.54 9.00 8.60
    Condizione D (20°C - 27/19) Pdc kW 1.68 1.63 2.36
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.36 10.70 12.04
    Condizione C (25°C - 27/19) Pdc kW 1.53 1.66 2.38
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 12.23 11.86 11.22
    Condizione A (35°C - 27/19) Pdc kW 2.50 3.50 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 6.18 5.27 4.36
    Condizione B (30°C - 27/19) Pdc kW 1.84 2.58 3.71
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 8.92 7.66 6.69
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 831 1,100 1,427
    Pdesign kW 3.50 4.50 5.60
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.66 0.91 1.02
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+++ A+++ A+++
    TBivalent Pdh (capacità dichiarata di risc.) kW 3.10 3.98 4.95
      Tbiv (temp. bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 4.10 3.91 3.82
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.21 1.56 1.94
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 7.56 7.45 7.25
    TOL Tol (temperatura limite di esercizio) °C -15 -15 -15
      Pdh (capacità dichiarata di risc.) kW 2.41 2.94 3.97
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 3.18 3.25 2.98
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 3.10 3.98 4.95
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 4.10 3.91 3.82
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 0.79 0.69 0.91
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 8.30 8.09 6.33
    Cond. B (2°C) Pdh (capacità dichiarata di risc.) kW 1.88 2.42 3.02
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.81 5.57 5.42
Capacità di Raffrescamento Nom. Btu/ora 8,500 11,900 17,100
  Min. kW 0.6 0.6 0.6
  Nom. Kcal/ora 2,150 3,010 4,300
  Max. kW 3.9 5.3 5.8
  Min. Kcal/ora 520 520 520
  Min. Btu/ora 2,000 2,000 2,000
  Nom. kW 2.5 3.5 5.0
  Max. Btu/ora 13,100 18,100 19,400
  Max. Kcal/ora 3,350 4,560 4,990
Pck (Modo riscaldamento del carter) W 0.0 0.0 0.0
Efficienza nominale Consumo energetico annuale kWh 205 (0.000) 330 (0.000) 550 (0.000)
  Classe energetica Riscaldamento A A A
  Nominal efficiency-=-Cop 6.10 (1) 5.30 (1) 4.55 (1)
Riscaldamento Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Collegamenti tubazioni Liquid DE mm 6.35 6.35 6.35
  Gas DE mm 9.5 9.5 9.5
Capacità di riscaldamento Min. Btu/ora 2,000 2,000 2,000
  Nom. Btu/ora 9,600 17,100 21,500
  Max. Kcal/ora 6,450 7,740 8,080
  Max. Btu/ora 25,500 30,700 32,000
  Nom. kW 3.6 5.0 6.3
  Min. kW 0.6 0.6 0.6
  Nom. Kcal/ora 2,150 2,150 5,420
  Min. Kcal/ora 520 520 520
  Max. kW 7.5 9.0 9.4
Pto (Thermostat off) W 6.0 6.0 6.0
Potenza assorbita Raffrescamento Min. kW 0.11 0.11 0.11
    Nom. kW 0.41 0.66 1.10
    Max. kW 0.88 1.33 1.60
  Riscaldamento Max. kW 2.01 2.53 2.64
    Min. kW 0.10 0.10 0.10
    Nom. kW 0.62 1.00 1.41
Stagione fredda inclusa Sì Sì Sì
Current Corrente di funzionamento nominale - 50Hz Riscaldamento A 2.9 (3), 2.8 (4), 2.7 (5) 4.6 (3), 4.4 (4), 4.3 (5) 6.5 (3), 6.2 (4), 6.0 (5)
    Raffrescamento A 2.0 (3), 1.9 (4), 1.9 (5) 3.1 (3), 2.9 (4), 2.8 (5) 5.1 (3), 4.9 (4), 4.6 (5)
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale
  220V 220V 220V
  230V 230V 230V
  240V 240V 240V