Specifiche Tecniche FVXG-K / RXG-K

FVXG25K2V1B / RXG25K3V1B FVXG25K2V1B / RXG25K2V1B FVXG35K2V1B / RXG35K3V1B FVXG35K2V1B / RXG35K2V1B FVXG50K2V1B / RXG50K3V1B FVXG50K2V1B / RXG50K2V1B
Poff (Modo spento) W 1.0   1.0   20.0  
Raffrescamento Psb (Consumo di energia in modo attesa - raffrescamento) W 1.0   1.0   20.0  
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25   0.25  
Eurovent Livello potenza sonora unità interna Raffrescamento Nom. dBA 52 54 52 55 58 56
  Livello potenza sonora unità esterna Cooling Nom. dBA 62   64   63  
Eff. stagionale (secondo EN14825) Raffrescamento Pdesign kW 2.50   3.50   5.00  
    Consumo energetico annuale kWh 135   194   330  
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.46   6.33   5.31  
    Condizione D (20°C - 27/19) Pdc kW 1.87   1.89   2.12  
      potenza assorbita kW         0.20  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.49   10.24   10.41  
    Condizione C (25°C - 27/19) potenza assorbita kW         0.32  
      Pdc kW 1.76   1.80   2.37  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.42   8.09   7.43  
    Condizione A (35°C - 27/19) potenza assorbita kW         1.61  
      Pdc kW 2.50   3.50   5.00  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.29   3.52   3.11  
    Condizione B (30°C - 27/19) Pdc kW 1.84   2.58   3.68  
      potenza assorbita kW         0.74  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.82   5.58   4.94  
  Risc. (Condizioni clim. medie) Consumo energetico annuale kWh 858   1,103   1,559  
    Pdesign kW 2.80   3.10   4.60  
    Richiesta cap. di risc. di riserva alle cond. di prog. kW 0.50   0.61   0.84  
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+   A   A+  
    TBivalent Pdh (capacità dichiarata di risc.) kW 2.48   2.74   4.07  
      Potenza assorbita kW         1.70  
      Tbiv (temp. bivalente) °C -7   -7   -7  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.72   2.35   2.39  
    Cond. C (7°C) Pdh (capacità dichiarata di risc.) kW 1.45   1.36   1.62  
      Potenza assorbita kW         0.30  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.10   5.13   5.37  
    TOL Tol (temperatura limite di esercizio) °C -15   -15   -15  
      Pdh (capacità dichiarata di risc.) kW 1.99   2.09   3.24  
      Potenza assorbita kW         1.60  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.32   1.93   2.02  
    Cond. A (-7°C) Pdh (capacità dichiarata di risc.) kW 2.48   2.74   4.07  
      Potenza assorbita kW         1.70  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.72   2.35   2.39  
    Cond. D (12°C) Pdh (capacità dichiarata di risc.) kW 1.69   1.59   1.90  
      Potenza assorbita kW         0.29  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.24   6.25   6.60  
    Cond. B (2°C) Potenza assorbita kW         0.57  
      Pdh (capacità dichiarata di risc.) kW 1.51   1.66   2.47  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.95   4.20   4.34  
Capacità di Raffrescamento Nom. Btu/ora 8,500 (2) 8,500 (3) 11,900 (2) 11,900 (3) 17,100 (2) 17,100 (3)
  Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Nom. Kcal/ora 2,150 (2) 2,150 (3) 3,010 (2) 3,010 (3) 4,300 (2) 4,300 (3)
  Max. kW 3.0 3.0 3.8 3.8 5.6 5.6
  Min. Kcal/ora 1,120 1,120 1,200 1,200 1,460 1,460
  Min. Btu/ora 4,400 4,400 4,800 4,800 5,800 5,800
  Nom. kW 2.5 (2) 2.5 (3) 3.5 (2) 3.5 (3) 5.0 (2) 5.0 (3)
  Max. Btu/ora 10,200 10,200 13,000 13,000 19,100 19,100
  Max. Kcal/ora 2,580 2,580 3,270 3,270 4,820 4,820
Pck (Modo riscaldamento del carter) W 0.0   0.0   0.0  
Efficienza nominale Annual energy consumption kWh 275 (0.000) 275 (0.000) 475 (0.000) 475 (0.000) 760 (0.000) 760 (0.000)
  Classe energetica Riscaldamento A A A A A A
  Nominal efficiency-=-Cop 4.55 4.55 3.68 3.68 3.29 3.29
Riscaldamento Heating-=-Heating cdh degradation heating 0.25   0.25   0.25  
Collegamenti tubazioni Liquid DE mm 6.35 6.35 6.35 6.35 6.35 6.35
  Gas DE mm 9.5 9.5 9.5 9.5 12.7 12.7
  Scarico DE mm 18 18 18 18 18 18
  Isolamento termico Sulla linea del liquido e su quella del gas Sulla linea del liquido e su quella del gas Sulla linea del liquido e su quella del gas Sulla linea del liquido e su quella del gas Sulla linea del liquido e su quella del gas Sulla linea del liquido e su quella del gas
Capacità di riscaldamento Min. Btu/ora 4,400 4,400 4,800 4,800 5,800 5,800
  Nom. Btu/ora 11,600 (3) 11,600 (4) 15,400 (3) 15,400 (4) 19,800 (3) 19,800 (4)
  Max. Kcal/ora 3,870 3,870 4,300 4,300 6,970 6,970
  Max. Btu/ora 15,400 15,400 17,100 17,100 27,600 27,600
  Nom. kW 3.4 (3) 3.4 (4) 4.5 (3) 4.5 (4) 5.8 (3) 5.8 (4)
  Min. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Nom. Kcal/ora 2,920 (3) 2,920 (4) 3,870 (3) 3,870 (4) 4,990 (3) 4,990 (4)
  Min. Kcal/ora 1,120 1,120 1,200 1,200 1,460 1,460
  Max. kW 4.5 4.5 5.0 5.0 8.1 8.1
Pto (Thermostat off) W 60.0   60.0   60.0  
Potenza assorbita Raffrescamento Min. kW 0.300 0.300 0.310 0.310 0.450 0.450
    Nom. kW 0.550 0.550 0.950 0.950 1.520 1.520
    Max. kW 0.790 0.790 1.150 1.150 2.000 2.000
  Riscaldamento Max. kW 1.270 1.270 1.460 1.460 2.660 2.660
    Min. kW 0.290 0.290 0.290 0.290 0.500 0.500
    Nom. kW 0.780 0.780 1.210 1.210 1.580 1.580
Stagione fredda inclusa Sì   Sì   Sì  
Corrente Corrente di funzionamento nominale - 50Hz Riscaldamento A 4.1 (4), 3.9 (5), 3.7 (6) 4.1 (5), 3.9 (6), 3.7 (7) 6.0 (4), 5.7 (5), 5.5 (6) 6.0 (5), 5.7 (6), 5.5 (7) 7.3 (5), 7.0 (6), 6.7 (7) 7.3 (5), 7.0 (6), 6.7 (7)
    Raffrescamento A 3.0 (4), 2.9 (5), 2.8 (6) 3.0 (5), 2.9 (6), 2.8 (7) 4.8 (4), 4.6 (5), 4.4 (6) 4.8 (5), 4.6 (6), 4.4 (7) 7.1 (5), 6.7 (6), 6.5 (7) 7.1 (5), 6.7 (6), 6.5 (7)
Note Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Classe energetica: dalla classe A (più efficiente) alla classe G (meno efficiente) Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Classe energetica: dalla classe A (più efficiente) alla classe G (meno efficiente) Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE Classe energetica: dalla classe A (più efficiente) alla classe G (meno efficiente)
  Raffreddamento: temp. interna 27°CBS, 19°CBU; temp. esterna 35°CBS, 24°CBU Consumo energetico annuale: sulla base di un consumo medio di 500 ore di esercizio all'anno a pieno carico (condizioni nominali) Raffreddamento: temp. interna 27°CBS, 19°CBU; temp. esterna 35°CBS, 24°CBU Consumo energetico annuale: sulla base di un consumo medio di 500 ore di esercizio all'anno a pieno carico (condizioni nominali) Raffreddamento: temp. interna 27°CBS, 19°CBU; temp. esterna 35°CBS, 24°CBU Consumo energetico annuale: sulla base di un consumo medio di 500 ore di esercizio all'anno a pieno carico (condizioni nominali)
  Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU Raffreddamento: temp. interna 27°CBS, 19°CBU; temp. esterna 35°CBS, 24°CBU Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU Raffreddamento: temp. interna 27°CBS, 19°CBU; temp. esterna 35°CBS, 24°CBU Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU Raffreddamento: temp. interna 27°CBS, 19°CBU; temp. esterna 35°CBS, 24°CBU
  Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU Raffreddamento: temp. interna 27°CBS, 19°CBU, temp. esterna 35°CBS, 24°CBU Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU Raffreddamento: temp. interna 27°CBS, 19°CBU, temp. esterna 35°CBS, 24°CBU Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU Raffreddamento: temp. interna 27°CBS, 19°CBU, temp. esterna 35°CBS, 24°CBU
  220V Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU 220V Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU 220V Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU
  230V Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU 230V Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU 230V Riscaldamento: temp. interna 20°CBS; temp. esterna 7°CBS, 6°CBU
  240V 220V 240V 220V 240V 220V
  Se collegato a un’unità esterna multi, consultare le specifiche dell’unità esterna multi da collegare. 230V Se collegato a un’unità esterna multi, consultare le specifiche dell’unità esterna multi da collegare. 230V Se collegato a un’unità esterna multi, consultare le specifiche dell’unità esterna multi da collegare. 230V
  Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale 240V Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale 240V Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale 240V
    Se collegato a un’unità esterna multi, consultare le specifiche dell’unità esterna multi da collegare.   Se collegato a un’unità esterna multi, consultare le specifiche dell’unità esterna multi da collegare.   Se collegato a un’unità esterna multi, consultare le specifiche dell’unità esterna multi da collegare.
    Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale   Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale   Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale