ABQ100CV1 / AZQS100B7V1B |
ABQ125CV1 / AZQS125B7V1B |
ABQ140CV1 / AZQS140B7V1B |
Poff (Modo spento) |
W |
0.0 |
|
|
Raffrescamento |
Psb (Consumo di energia in modo attesa - raffrescamento) |
W |
9.0 |
|
|
|
Cooling-=-Cooling cdc degradation cooling |
0.25 |
|
|
Eff. stagionale (secondo EN14825) |
Raffrescamento |
Pdesign |
kW |
9.50 |
|
|
|
|
Consumo energetico annuale |
kWh |
716 |
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy label |
4.65 |
|
|
|
|
Condizione D (20°C - 27/19) |
Pdc |
kW |
4.20 |
|
|
|
|
|
potenza assorbita |
kW |
0.58 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd |
7.35 |
|
|
|
|
Condizione C (25°C - 27/19) |
potenza assorbita |
kW |
0.76 |
|
|
|
|
|
Pdc |
kW |
4.50 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd |
5.94 |
|
|
|
|
Condizione A (35°C - 27/19) |
potenza assorbita |
kW |
3.63 |
|
|
|
|
|
Pdc |
kW |
9.50 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd |
2.62 |
|
|
|
|
Condizione B (30°C - 27/19) |
Pdc |
kW |
7.00 |
|
|
|
|
|
potenza assorbita |
kW |
1.86 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd |
3.78 |
|
|
|
Risc. (Condizioni clim. medie) |
Consumo energetico annuale |
kWh |
2,498 |
|
|
|
|
Pdesign |
kW |
6.78 |
|
|
|
|
Richiesta cap. di risc. di riserva alle cond. di prog. |
kW |
3.89 |
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop |
A |
|
|
|
|
TBivalent |
Pdh (capacità dichiarata di risc.) |
kW |
6.00 |
|
|
|
|
|
Potenza assorbita |
kW |
2.20 |
|
|
|
|
|
Tbiv (temp. bivalente) |
°C |
-7 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop |
2.73 |
|
|
|
|
Cond. C (7°C) |
Pdh (capacità dichiarata di risc.) |
kW |
3.00 |
|
|
|
|
|
Potenza assorbita |
kW |
0.56 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop |
5.43 |
|
|
|
|
TOL |
Tol (temperatura limite di esercizio) |
°C |
-15 |
|
|
|
|
|
Pdh (capacità dichiarata di risc.) |
kW |
7.70 |
|
|
|
|
|
Potenza assorbita |
kW |
4.33 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop |
1.78 |
|
|
|
|
Cond. A (-7°C) |
Pdh (capacità dichiarata di risc.) |
kW |
6.00 |
|
|
|
|
|
Potenza assorbita |
kW |
2.20 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop |
2.73 |
|
|
|
|
Cond. D (12°C) |
Pdh (capacità dichiarata di risc.) |
kW |
3.50 |
|
|
|
|
|
Potenza assorbita |
kW |
0.55 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop |
6.45 |
|
|
|
|
Cond. B (2°C) |
Potenza assorbita |
kW |
1.05 |
|
|
|
|
|
Pdh (capacità dichiarata di risc.) |
kW |
3.70 |
|
|
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop |
3.55 |
|
|
Capacità di Raffrescamento |
Nom. |
kW |
9.5 |
12.1 |
13.0 |
Pck (Modo riscaldamento del carter) |
W |
0.0 |
|
|
Efficienza nominale |
Annual energy consumption |
kWh |
1,813 |
2,153 |
2,159 |
|
Classe energetica |
Riscaldamento |
D |
|
B |
|
Nominal efficiency-=-Cop |
2.62 |
|
3.01 |
Riscaldamento |
Psb (Consumo di energia in modo attesa - riscaldamento) |
W |
9.0 |
|
|
|
Heating-=-Heating cdh degradation heating |
0.25 |
|
|
Capacità di riscaldamento |
Nom. |
kW |
10.8 |
13.5 |
15.5 |
Pto (Thermostat off) |
W |
109.0 |
|
|
Potenza assorbita |
Raffrescamento |
Nom. |
kW |
3.63 |
|
4.32 |
|
Riscaldamento |
Nom. |
kW |
3.16 |
|
4.55 |
Stagione fredda inclusa |
sì |
|
|
Note |
Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale |
|
Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale |
Efficienza nominale |
EER |
|
|
2.81 |
|
|
COP |
|
|
3.41 |
|
|
Classe energetica |
Raffreddamento |
|
|
C |
|
|
|
Riscaldamento |
|
|
B |
|
Note |
|
(1) - Valori EER/COP conformi allo standard Eurovent 2012, solo per l'uso fuori dall'UE |
|
|
|
(2) - Efficienza nominale: raffrescamento a 35°/27° carico nominale, riscaldamento a 7°/20° carico nominale |
|